Product Description
Train number detection
The new ECoSDetector RC can monitor its 4 track sectors in a special way: with the aid of the RailCom® technology (“local detector”) one can not only find out if the track is occupied but also exactly which train is located there (train number detection). Of course, you must have RailCom® capable locomotive decoders.
Clever
Knowing which train is located where leads to new functions in conjunction with the route setting feature of the ECoS: you may, for instance, activate level crossing booms automatically or the train search for an unoccupied track in the storage yard. The switching inputs respectively track occupancy sensors are electronically “entprellt“ in order to assure reliable feedback even in case of poor contact or pretty dirty tracks.
Connection to ECoSlink
Each ECoSDetector RC is directly wired to the command station via the EcoSlink bus. Besides the ECoS command station all types of the Central Station® Reloaded with ESU update are suitable. The galvanic separation of the bus system and the command station assures best possible reliability and data transfer to the command station. The command station automatically detects and registers all ECoSDetector modules. The devices can be comfortably and easily configured with the command station, which can also be done after installing the devices.
Future proof
The operating software of each ECoSDetector can be updated and expanded to facilitate additional functions, if necessary: whenever necessary this update will be accomplished automatically by the command station. Thus your ECoSDetector is technically always up-to-date.
ECoSDetector | |
---|---|
Operational modes: | Direct bus connection to ECoSlink. Operation with ECoS or Central Station Reloaded V3.0.0. is possible. |
Feedback section: | 16 feedback modules. |
Configurable by using jumpers as digital inputs (e.g. for contact tracks or reed switches) or as track occupancy detectors (current sensor). | |
Galvanical isolation of feedback modules and command station | |
Max. 3A current load per feedback input | |
RailCom®: | 4 of 16 feedback sections can be used as RailCom feedback sections ("local detector"), if desired. Recognition of loco address |
Dimensions: | 86mm x 86mm x 25mm (3.39 x 3.39 x 0.98 inch) |
Included in delivery: | ECoSDetector feedback module, terminals, ECoSlink bus connection cable, extensive instruction manual |
ECoSDetector Standard | |
Operational modes: | Directly connected to ECoSlink bus. Operation with ECoS command station and Central Station Reloaded V3.0.0 possible. |
Feedback section: | 16 feedback modules as digital inputs (e.g. for contact tracks or reed switches). Galvanical isolation of feedback modules and command station. |
Dimensions: | 86mm x 86mm x 25mm (3.39 x 3.39 x 0.98 inch) |
Included in delivery: | ECoSDetector Standard feedback module, terminals, ECoSlink bus connection cable, extensive instruction manual |
ECoSDetector RC | |
Operational modes: | Directly connected to ECoSlink bus. Operation with ECoS command station and Central Station Reloaded V3.0.0 possible. |
Feedback section: | 4 feedback inputs configured as track occupancy detectors (current sensor). Galvanical isolation of feedback modules and command station. |
RailCom®: | 4 feedback sections can be used as RailCom feedback sections ("local detector"). Recognition of loco address |
Dimensions: | 86mm x 86mm x 25mm (3.39 x 3.39 x 0.98 inch) |
Included in delivery: | ECoSDetector RC feedback module, terminals, ECoSlink bus connection cable, extensive instruction manual |
ECoSDetector Extension | |
Operational modes: | Extension module for ECoSDector, is powered and controlled by it. Transistor outputs are powered externally. |
Outputs: | 32 transistor outputs, 100mA output load each. Construction as „open collector“ is connected to ground |
Total current of all outputs is max. 1.5A | |
Dimensions: | 86mm x 86mm x 25mm (3.39 x 3.39 x 0.98 inch) |
Included in delivery: | ECoSDetector Extension module, terminals, extensive instruction manual |